Operating Principle
When the temperature in the circuit increases to Rated Tripping Temp. (TF), Thermal fuse can detect it and inside fusible alloy will be melted and contracted to a ball shape under the help of surface tension and specific resin material to further cut the circuit fatally.
Unit:mm
1. Rated Tripping temperature (TF):90~150℃
2. Holding Temperature (TC):55~120℃
3. Maximum Temperature (TM):180℃
4. Rated Voltage (Ur):250V
5. Rated Current (Ir): 1A~5A